The American School of Gas Measurement Technology (ASGMT) has been at the forefront of Flow Measurement training since its inception in 1966. Over the years, ASGMT has evolved to encompass comprehensive training in both gas and liquids measurement. With a commitment to excellence, ASGMT now offers an extensive curriculum comprising over 115 lecture classes, complemented by 48 Hands-On Product Training sessions led by industry experts.

School

September 16th – 19th, 2024

HOW TO PERFORM A LOST & UNACCOUNTED-FOR GAS PROGRAM

Explore the Latest Papers at ASGMT

  • Home
  • |
  • Papers
  • |
  • HOW TO PERFORM A LOST & UNACCOUNTED-FOR GAS PROGRAM

Papers by year

Select Year

October 1, 2018

any (likely most) gas pipeline companies struggle with lost-and-unaccounted-for-gas (L&U) and it can be a significant cost to their bottom line as shown below.

As shown in this inset, by reducing L&U from 0.6 percent to .25 percent, a typical company with a 2 BCF daily throughput could save Over 7.6 million dollars annually based on $3.00 gas prices, which is a daily loss of $21,000.

730,000,000

0.6%

4,380,000

730,000,000

0.25%

1,825,000

4,380,000

(1,825,000)

2,555,000 $3.00

$7,665,000

MMBtu Annual Throughput Average Percentage of L&U MMBtu Lost Annually

MMBtu Annual Throughput Average Percentage of L&U MMBtu Lost Annually

MMBtu Lost Annually at .6 Percent MMBtu Lost Annually at .25 Percent MMBtu Potential from Loss Reduction Price per MMBtu

Value Potential from Loss Reduction

FIGURE 1. L&U Reduction Value Example

NOTE: For simplicity, the formula assumed a Btu factor of 1,000.

Key Considerations

Now that you see the amount of money your company can save by performing a lost and unaccounted for gas program, you need to consider the key issues to achieving the goal, and making it sustainable.

  •   First, you will need management’s “buy in” to insure cooperation throughout the lost and unaccounted for process and the company must be willing to make changes. Those changes involve implementing industry “best practices” for measurement and gas loss control, i.e.
    •   A state-of-the-art, measurement collection, balancing, and reporting system,
    •   Pipeline segmentation for loss control,
    •   Well trained people in both the field and measurement support,
    •   Regional Measurement Specialists,
    •   The proper equipment for testing and calibration,
    •   Good standards and procedures, etc.